Cummins, Perkins & Deutz diesel generators in Lahore, Pakistan

Brand-new Cummins, Perkins and Deutz diesel generators from 20 to 1000 kVA — sized against your measured load, installed turnkey with canopy and ATS, and serviced from parts that sit on our own shelf in Lahore.

  • Genuine Cummins · Perkins · Deutz
  • Free load calculation & site survey
  • 3 Lahore showrooms
  • Nationwide service & spares
Cummins 500 kVA open generator set seen from the side, with QSZ13 engine, alternator and radiator
Cummins/QSZ13-G3
Cummins 500 kVA
500 kVA
Rated output
720 A
Per phase
Textile millsHospitalsHousing societiesCommercial towersCold storageCement plantsHotelsPoultry farmsData centresIndustrial estates
0+
Years supplying power
0
Lahore showrooms
0
Genuine engine brands
0/7
Breakdown response
Look inside

Turn it. Open it. See what you are buying.

A silent generator is a box until someone lifts the lid. Drag the set to turn it, then lift the canopy to see what sits inside.

  • 1Diesel engine
  • 2Alternator
  • 3Radiator and fan
  • 4Control panel
  • 5Fuel tank
  • 6Sound-attenuated canopy

Illustrative model of a canopy generator set. Your unit is built around the Cummins, Perkins or Deutz engine you choose.

Drag to turn
04 — Applications

Sized around what you actually run.

A textile floor, a hospital and a housing society are three different problems that happen to need the same category of machine. The rating, the engine and the transfer scheme change with each one.

Textile & manufacturing

01

Looms, compressors and motors starting together is the hardest duty there is. Sized for step load, not just running load.

Typical250 – 1000 kVA

Commercial towers

02

Lifts, HVAC and pressurisation on automatic transfer, with a fuel curve a finance team will sign off on.

Typical100 – 650 kVA

Housing societies

03

Common-area power, tube wells and street lighting, with silent canopies specified to keep residents from complaining.

Typical60 – 250 kVA

Hospitals & clinics

04

Theatres and imaging cannot see the changeover gap. Sets paired with UPS so the load never notices the grid dropped.

Typical40 – 500 kVA

Cold storage & food

05

Compressor starting current and non-negotiable continuity. Losing the room costs more than the generator did.

Typical40 – 350 kVA

Industrial plants

06

Continuous process duty where the set is the grid, not the backup. Prime-rated, bulk fuelled, paralleled for N+1.

Typical350 – 1000 kVA
06 — Why us

Anyone can sell you a generator.

The difference shows up two years later, at 2am, when it will not start and you need someone to pick up the phone.

01

Genuine Cummins, Perkins and Deutz

Brand-new, certified units from three global engine makers — nothing rebuilt, nothing relabelled. The engine number on the plate is the engine you paid for, and we hand over the documentation that proves it.

02

Specified for this climate, not a brochure

Radiators and air paths sized for 50 °C ambient and heavy dust. A set specified against a European datasheet derates exactly when a Pakistani summer needs it most.

03

Turnkey — load calculation to live handover

Load study, sizing, delivery, foundation, soundproof canopy, ATS panel integration and commissioning under real load. One contract, one team, one number to call.

04

Parts on the shelf at Brandreth Road

Filters, belts, injectors and controllers stocked in the middle of Lahore's machinery market. A part that has to be imported is a week of downtime you cannot afford.

05

Nationwide service, not just Lahore delivery

Commissioning and scheduled maintenance across Pakistan, with coverage for your city agreed in writing before you buy rather than discovered afterwards.

06

Three showrooms you can actually walk into

Ready stock on the floor at Thokar Niaz Baig, Brandreth Road and Khayaban-e-Jinnah. Inspect the set, watch an ATS transfer live, then decide.

07 — How it works

From first message to a set that runs itself.

Five steps. No stage where you are handed to a different company and told to explain it all again.

  1. 01

    Tell us what has to keep running

    A call or a WhatsApp message is enough to start. Connected load, machine list, or a photo of your distribution board — whatever you have to hand.

  2. 02

    We calculate the load and pick the engine

    An engineer measures running and starting load, then recommends both a rating and a brand — Cummins for heavy step load, Perkins for fuel economy, Deutz for harsh continuous duty — with the reasoning written down.

  3. 03

    Inspect the set before you commit

    Come to the showroom and see the unit, the canopy finish and the ATS panel. For ratings we do not hold on the floor, we arrange an inspection at a commissioned site.

  4. 04

    Itemised quote, nothing buried in it

    Set, canopy, ATS panel, cabling, civil work, transport and commissioning — line by line. You see what each part costs before you commit to any of it.

  5. 05

    Delivery, installation and live commissioning

    Transport, foundation, electrical connection and transfer-switch integration, then a test under real load with your team watching the changeover happen.

  6. 06

    Servicing for as long as you run it

    Maintenance scheduled on runtime hours, genuine filters and spares from our own stock, and a breakdown line a human answers. Annual contracts available from commissioning day.

08 — Questions

The things people ask before buying.

Not covered here? Send us your appliance list or a photo of your distribution board and we will size it for you at no cost.

Ask an engineer
  • It depends on the duty, not the badge. Cummins is the answer where heavy step load is the problem — textile floors, plants where everything starts at once — and it has the widest parts network in Pakistan. Perkins wins on fuel consumption at part load, which is where a commercial building's set spends its life, so it usually costs less to own on a tower or a housing society. Deutz is for harsh continuous duty: dust, heat and a process that is not allowed to stop, with longer service intervals to match. We recommend one after seeing the load, not before.

  • It comes down to running load and, more importantly, starting load — motors, compressors and air conditioners draw several times their rated current for a moment at startup. We run a load calculation on site before quoting, so the rating is measured rather than estimated. Oversizing is not the safe option it looks like: a set running lightly wet-stacks, burns fuel it never needed to burn, and costs more to maintain for its whole life.

  • Brand-new and certified. We supply genuine Cummins, Perkins and Deutz powered sets with documentation, and we do not deal in rebuilt or relabelled engines. You are welcome to inspect the engine plate and the paperwork at the showroom before anything is paid.

  • Sets with an automatic transfer switch start and take load within roughly 8 to 15 seconds. Where even that gap is unacceptable — operating theatres, servers, telecom — we pair the set with a UPS so the load never sees an interruption at all. You can watch a live ATS transfer at the Khayaban-e-Jinnah display centre before you decide.

  • Yes — canopy fabrication, ATS panel integration, cabling, foundation and exhaust routing are all part of the turnkey scope. It is quoted line by line rather than hidden inside a headline price, so you can see exactly what the installation costs alongside the set.

  • Our canopy units measure between 63 and 82 dB(A) at 7 metres depending on rating — the smaller commercial sets sit close to normal conversation from across a lawn. Exhaust routing and where the set is placed matter as much as the canopy itself, which is part of what the site survey settles.

  • Routine servicing follows runtime hours rather than the calendar — typically every 250 running hours for oil and filters, with a fuller inspection annually. Genuine filters, belts, injectors and controllers for all three brands are stocked at our Brandreth Road branch, so a routine service does not wait on an import. Annual maintenance contracts bundle the visits, the parts and priority breakdown response into one predictable figure.

  • Yes. Delivery, installation and commissioning are available nationwide, and we service sets across Pakistan. Transport is quoted separately and transparently based on distance and the rating of the set, and service coverage for your city is agreed in writing before you buy.

  • Every set carries a 24-month warranty covering engine and alternator, handled at your premises — you never have to transport a generator anywhere. Warranty requires servicing to be kept to schedule, which is one reason most customers put the maintenance contract in place from commissioning day.

  • Because a real figure depends on the rating, the engine brand, the canopy and ATS specification, and the installation scope — and on the exchange rate on the day. Publishing a number that is wrong by the time you read it helps nobody. Send us the load and you will have an itemised quote, usually the same day.

Next step

A free site survey, an honest recommendation on rating, and an itemised quote with nothing buried in it. No obligation either way.

Mon – Sat, 9:00 AM – 8:00 PM